pH sensors

DULCOTEST

Graduated pH measuring ranges 0 – 14

pH measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real-time. Control, regulate and monitor chemical processes with the aid of precise measured values.

Reliable online measurement of pH values – with DULCOTEST sensors

The online measurement and adjustment of pH values must be as accurate, fast and reliable as possible and provide good availability of the measured values, be it for the monitoring, control or regulation of chemical processes.

Our product line of DULCOTEST pH sensors provides a wide range of pH sensors for different measuring tasks.

Our pH sensors are manufactured to very strict quality controls (e.g. in accordance with RoHS guidelines). Routine steps are automated but critical steps are carried out manually under expert supervision. In this way we achieve the best reproducible quality and cost reduction.

Your benefits

  • Precise and reliable pH measurement enables efficient processes and excellent process reliability
  • The wide choice of sensor types with different constructions makes them reliable components in many applications
  • A long service life is achieved through the use of the best quality materials for the glass and diaphragms, a stable reference system and optimised production. This minimises both downtime and maintenance
  • With short storage times and fast delivery, your pH sensors can be up and running very quickly and you can make maximum use of their service life (all glass sensors start to age as soon as they leave production)
  • Wide range of special versions for fitting length, cable length and plugs for made-to-measure connection to your process
  • Unique label for OEM partners

Technical Info

  • Selection of sensor type according to the application
  • The insertion angle must be > 15° from the horizontal (except with PHEK-L: horizontal to vertical)
  • Maximum flow < 0.8 m/s
  • With cable lengths > 10 m, use the 4-20 mA transducer type PHV1
  • Calibration using quality buffer solutions

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Diaphragm and reference system optimised for use in swimming pools and for potable water
  • Ceramic diaphragm with special material, optimised size and optimised pore diameter
  • Long service life due to reduced diffusion (‘bleeding’) of the electrolyte
  • Long service life due to the material, which is inert to aggressive disinfectants
  • Stable reference system
  • Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Diaphragm and reference system optimised for use in swimming pools and for potable water
  • Ceramic diaphragm with special material, optimised size and optimised pore diameter
  • Long service life due to reduced diffusion (‘bleeding’) of the electrolyte
  • Long service life due to the material, which is inert to aggressive disinfectants
  • Stable reference system
  • Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Diaphragm and reference system optimised for use in swimming pools and for potable water
  • Ceramic diaphragm with special material, optimised size and optimised pore diameter
  • Long service life due to reduced diffusion (‘bleeding’) of the electrolyte
  • Long service life due to the material, which is inert to aggressive disinfectants
  • Stable reference system
  • Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Diaphragm and reference system optimised for use in swimming pools and for potable water
  • Ceramic diaphragm with special material, optimised size and optimised pore diameter
  • Long service life due to reduced diffusion (‘bleeding’) of the electrolyte
  • Long service life due to the material, which is inert to aggressive disinfectants
  • Stable reference system
  • Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Solid high-grade plastic housing with integrated process connection for direct installation in the process with ½” and ¾” NPT thread
  • Large dirt-repellent Teflon diaphragm protects against unwanted blocking of the reference
  • Double junction reference system for stability with chemically polluted water
  • Large electrolyte reservoir for long service lives

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • The large dirt-repellent Teflon® diaphragm prevents the reference system from becoming blocked up
  • Long service life when solids are present
  • High-viscosity electrolyte combined with a salt reservoir prevents the electrolyte from ‘bleeding’
  • Long service life without drifts when there is clear water with low conductivity
  • Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • The large dirt-repellent Teflon® diaphragm prevents the reference system from becoming blocked up
  • Long service life when solids are present
  • High-viscosity electrolyte combined with a salt reservoir prevents the electrolyte from ‘bleeding’
  • Long service life without drifts when there is clear water with low conductivity
  • Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Diaphragm and reference system optimised for extremely high solids content
  • The solid electrolyte makes the diaphragm redundant and prevents the reference system from becoming blocked up
  • Long service life when sludge is present due to lack of a diaphragm
  • Long service life as the solid electrolyte prevents the electrolyte from ‘bleeding’
  • Stable reference system
  • Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Diaphragm and reference system optimised for extremely high solids content
  • The solid electrolyte makes the diaphragm redundant and prevents the reference system from becoming blocked up
  • Long service life when sludge is present due to lack of a diaphragm
  • Long service life as the solid electrolyte prevents the electrolyte from ‘bleeding’
  • Stable reference system
  • Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Optimised pH glass for use in the presence of glass-corroding hydrofluoric acid (HF). HF is formed primarily in the presence of fluoride (F) at a pH of < 4. Glass corrosion is promoted by a constant concentration of fluoride, a falling pH value and a rising temperature. The glass composition and structure of the PHEF type reduce the release of SiF4. Extended service life in the presence of fluoride (F) at a pH of < 7
  • The flat shape of the glass diaphragm and large ring diaphragm facilitate use in contaminated water, which also contains abrasive solids

Your benefits

  • Electrochemical combination probe: pH and reference electrode integrated
  • Precise and reliable pH measurement in water containing fluoride with low pH enables efficient processes and excellent process reliability
  • A special pH glass and dirt-repellent double junction can extend the service life of the sensor and thereby minimise downtimes as well as maintenance requirements
  • The combination of hydrofluoric acid-resistant glass and PTFE double junction makes the sensor suited to gas scrubbing applications where fluoride and dirt may be encountered at the same time
  • Twist protection for the sensor cable connection ensures that the cable can remain connected during installation and removal of the sensor, reducing moisture on the plug-in contacts

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Renewable liquid electrolyte by continuous replenishment from an electrolyte bottle installed above the electrode
  • 1 ceramic diaphragm made of special material and with an optimised size / with optimised pore diameter
  • Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Long service life in the presence of chemicals dissolved in the water, which could contaminate the reference system
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Renewable liquid electrolyte through continuous replenishment from an electrolyte bottle installed above the electrode
  • 3 ceramic diaphragms made of special material, with optimised size and optimised pore diameter
  • Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Long service life in water with low conductivity of > 50 µS/cm and where solids are present
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Diaphragm and reference system optimised for use in swimming pools and for potable water
  • Ceramic diaphragm with special material, optimised size and optimised pore diameter
  • With plastic shaft to prevent glass breakage
  • Mechanical protection of the glass diaphragm
  • Long service life due to reduced diffusion (‘bleeding’) of the electrolyte
  • Long service life due to the material, which is inert to aggressive disinfectants
  • Stable reference system
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Diaphragm and reference system optimised for use in swimming pools and for potable water
  • Ceramic diaphragm with special material, optimised size and optimised pore diameter
  • With plastic shaft to prevent glass breakage
  • Mechanical protection of the glass diaphragm
  • Long service life due to reduced diffusion (‘bleeding’) of the electrolyte
  • Long service life due to the material, which is inert to aggressive disinfectants
  • Stable reference system
  • Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • With plastic shaft to prevent glass breakage
  • Horizontal (level) installation possible (90° angle) (usually limited to 0 – 75° angle)
  • Diaphragm and reference system optimised for use in swimming pools and for potable water
  • Ceramic diaphragm with special material and optimised size / optimised pore diameter
  • Long service life due to reduced diffusion (‘bleeding’) of the electrolyte
  • Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Long service life due to the material, which is inert to aggressive disinfectants
  • Stable reference system

Your benefits

  • Electrochemical combination electrode: pH and reference electrode integrated
  • Diaphragm and reference system optimised for exacting process requirements
  • Ceramic diaphragm with special material, optimised size and optimised pore diameter
  • Long service life due to reduced diffusion (“bleeding”) of the electrolyte
  • Long service life due to the material, which is inert to aggressive chemicals
  • Stable reference system for high pressure/temperature requirements
  • Integrated Pt 100 temperature sensor for temperature compensation of the pH measurement in higher-order measuring instruments eliminates the need for an additional sensor housing and external temperature sensor
  • VARIO Pin plug-in head with IP 67 specification
  • Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
  • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

Brand