Automatic visual inspection machine for ampoules, vials, cartridges and syringes.
The AV-E is the cutting-edge technology for the high-speed automatic inspection of pharmaceutical products such as vials, cartridges, ampoules¿ and syringes (mod. AV-EGS), ¿which represents the ideal solution to ensure that SVP products are essentially free of particulate and cosmetic defects.

Flow up to 36 m3/h
The UV system DULCODES LP TL for syrup disinfection declares war on heat-resistant germs. In instances when standard heat pasteurisation isn’t up to the job, UV light provides a very quick and efficient form of disinfection without the need for heat.
The UV system DULCODES LP TL can disinfect up to 36 m3/h of sugar syrup. The system uses an optimised flow with mixing zones in the thin-film reactors for optimum radiation of liquids. When working with viscous media with a low UV transmission of up to 20 %/cm in particular, UV disinfection saves energy and costs and can replace pasteurisation. Up to 99.99 % of heat-resistant spores can be eliminated which typically cannot be achieved by pasteurization. UV treatment with the DULCODES LP TL system has no negative impact on the quality, taste or appearance of the sugar syrup.
| Max. flow rate* | Max. flow rate** | Lamp power | Connected load | Dimensions L x W x H | |
|---|---|---|---|---|---|
| m3/h | m3/h | W | kW | mm | |
| 2x350 LP TL | 4 | 2.3 | 2x370 | 1.4 | 2,700 x 600 x 2,300 |
| 4x350 LP TL | 8 | 4.6 | 4x370 | 2.0 | 2,700 x 600 x 2,300 |
| 6x350 LP TL | 12 | 6.9 | 6x370 | 2.9 | 2,700 x 600 x 2,300 |
| 2 x 4x350 LP TL | 16 | 9.2 | 8x370 | 3.4 | 2,700 x 800 x 2,300 |
| 2 x 6x350 LP TL | 24 | 13.8 | 12x370 | 3.4 | 2,700 x 800 x 2,300 |
| 3 x 6x350 LP TL | 36 | 20.7 | 18x370 | 7.5 | 3,000 x 1,300 x 2,300 |
| * UV transmission > 38 %/cm; irradiation intensity 1.300 J/m2 | |||||
| ** UV transmission > 20 %/cm; irradiation intensity 1.300 J/m2 | |||||
| Lamp type | Low-pressure lamp VARIO Flux | ||||
| Control type | Siemens SPS with touch panel | ||||
| Permissible operating pressure | 10 bar | ||||
| Permissible ambient temperature | 5…40 °C | ||||
| Permissible medium temperature | 4…40 °C | ||||
| Enclosure rating | IP54 | ||||