Automatic visual inspection machine for ampoules, vials, cartridges and syringes.
The AV-E is the cutting-edge technology for the high-speed automatic inspection of pharmaceutical products such as vials, cartridges, ampoules¿ and syringes (mod. AV-EGS), ¿which represents the ideal solution to ensure that SVP products are essentially free of particulate and cosmetic defects.

7.5 – 12,000 g/h chlorine dioxide. Maximum volume of water that can be treated with metering of 0.2 ppm ClO2, depending on the size of the system: 60,000 m3/h
Chlorine dioxide system for the metering of chlorine dioxide with concentrated starting chemicals. The proven safety concept protects people and the environment. The certified yield guarantees efficient chlorine dioxide production. Bello Zon CDKd can be easily and safely integrated into any water treatment process.
In the chlorine dioxide system there is an intrinsically safe pre-dilution station for concentrated hydrochloric acid. The consumption of hydrochloric acid can therefore be automatically adapted on-site to the individual operating conditions by means of a patent-pending process.
The system control offers impressive and user-friendly menu navigation and ensures the precise production of chlorine dioxide. The chemicals are mixed perfectly in a reactor made of food-safe PVDF. You thereby benefit from maximum yield with the lowest possible consumption of chemicals and maximum operating safety. The requirements set by the Industry 4.0 standards of tomorrow are met thanks to communication via popular bus systems and our DULCONNEX Platform.
The construction and operating mode of the system also complies with all requirements of DVGW specifications W 224 and W 624 and the system is intended for operation with concentrated chemicals Bello Zon chlorite (24.5% NaClO2) and acid (25 – 37% HCl). The liquid levels of the starting chemicals can either be displayed and monitored by external liquid level sensors or by adaptive liquid level monitoring for which a patent has been applied.
Power supply
Inputs
Outputs
Operating substances
Degree of protection
Bus communication options
| Type | Chlorine dioxide metering rate (min.…max./hour, min./day)* | Max. operating pressure** | Operating temperature | Suction-side connector dimension of calibration vessels | Dimensions of the bypass connector | |||
|---|---|---|---|---|---|---|---|---|
| g/h | g/d | bar | °C | Chlorite | Acid | DN | ||
| CDKd 150 | 7.5…150 | 56 | 8 | 10…40 | 8x5 | 6x4 | 25 | |
| CDKd 400 | 20…400 | 140 | 8 | 10…40 | 12x9 | 8x5 | 25 | |
| CDKd 900 | 45…900 | 300 | 8 | 10…40 | Pressure hose nozzle d16 | 8x5 | 25 | |
| CDKd 2000 | 100…2,000 | 700 | 5 | 10…40 | Pressure hose nozzle d20 | 12x9 | 40 | |
| CDKd 2800 | 140…2,800 | 700 | 5 | 15…40 | Pressure hose nozzle d20 | 12x9 | 40 | |
| CDKd 7300 | 370…7,300 | 1750 | 3 | 15…40 | Pressure hose nozzle d32 | Pressure hose nozzle d16 | 40 | |
| CDKd 12000 | 600…12,000 | 1750 | 2 | 18…40 | Pressure hose nozzle d32 | Pressure hose nozzle d16 | 40 | |
| * The metering figures relate to 5 or 2 bar back pressure and an ambient temperature of 20 °C. The minimum capacity/hour is based on the fact that when the system is operating at below 5 % of the nominal capacity, continuous metering is no longer possible due to the fact that the metering pumps then have a low pumping frequency. The reactor contents should be changed at least twice daily with systems that do not work continuously. Therefore, do not operate the system below the stated minimum capacity/day. | ||||||||
| ** at an ambient temperature of 35 °C | ||||||||
| Type | Dimensions H x W x D (approx.)* | Weight | Supply voltage 230 V** | Supply voltage 115 V** | Power consumption without bypass pump | Power consumption with bypass pump | HCl (30 %)*** | NaClO2 (24.5 %)*** |
| mm | kg | A | A | W | W | l/h | l/h | |
| CDKd 150 | 1,300 x 1,000 x 250 | 89 | 3.9 | 1.7 | 110 | 640 | 0.9 | 0.9 |
| CDKd 400 | 1,675 x 900 x 460 | 119 | 3.9 | 1.8 | 160 | 690 | 2.5 | 2.5 |
| CDKd 900 | 1,920 x 920 x 520 | 131 | 4.2 | 2.3 | 210 | 740 | 5.6 | 5.6 |
| CDKd 2000 | 1,880 x 1,320 x 570 | 201 | - | 3.7 | 370 | - | 12.3 | 12.3 |
| CDKd 2800 | 1,880 x 1,320 x 570 | 201 | - | 3.7 | 370 | - | 17.3 | 17.3 |
| CDKd 7300 | 2,250 x 1,850 x 500 | 216 | - | 8.6 | 610 | - | 45.1 | 45.1 |
| CDKd 12000 | 2,250 x 1,850 x 500 | 216 | - | 8.6 | 610 | - | 74.1 | 74.1 |
| * including main system, pre-dilution and rinse valve, without bypass pump and water feed section | ||||||||
| ** 230 V figures with bypass pump, 115 V figures without bypass pump | ||||||||
| *** Sodium chlorite (NaClO2) 24.5 %, purity in accordance with EN 938, hydrochloric acid 25-36%, purity in accordance with EN 939. The chemical consumption may vary depending on the temperature. The hydrochloric acid consumption is calculated for a concentration of 30%. Up to 25% hydrochloric acid can be saved with the aid of automatic acid adjustment. | ||||||||
| Permissible relative air humidity (non-condensing) | max. 85% rel. |
| Permissible ambient temperature | 40 °C |
| Permissible temperature of chemicals | 10 … 35 °C |
| Storage and transport temperature | -10 … +40 °C |
| Degree of protection | IP 65 |