sensors for free chlorine

DULCOTEST

Graduated measuring ranges 0.01 – 200 mg/l, special measuring range up to 1,000 mg/l

The application-based DULCOTEST sensors for free chlorine deliver precise measured values and a high degree of monitoring and process reliability in any disinfection application.

Reliable online measurement of free (effective) chlorine – with DULCOTEST sensors.

Free chlorine is the most important disinfectant in the world. This term is used to refer to the compounds Cl2 (elementary chlorine), HOCl (hypochlorous acid) and OCl- (hypochlorite).

Our product line of DULCOTEST sensors for free chlorine provides five product ranges optimised for different applications. Each product range consists of several types with different measuring ranges.

The proven diaphragm-covered standard sensor for free chlorine CLE3 is used to monitor or control all types of clear water, for example in the disinfection of potable water. The variant CLE3.1 is especially suitable for an excess of combined chlorine, providing the most accurate results in the calculation of combined chlorine from the measurement of total chlorine and free chlorine.

Sensors CLB2 and CLB3 are easy-to-operate, low-cost chlorine sensors without a diaphragm for clear water without pollution.

Sensor CLO1 is particularly suitable for in-line electrolysis
processes where unwanted compounds may be formed; sensor CLO2 is also ideal for hot water disinfection.

Sensor CBR1 can be used in contaminated water, even for high pH values of up to 9.5, for example in the disinfection of cooling water.

Sensor CLR1 has been optimised for the disinfection or washing of foodstuffs and tolerates contaminated water and chlorine concentrations of up to 1,000 mg/l.

Your benefits

  • Five different sensor ranges and numerous different versions deliver the following benefits: use with a wide range of water qualities (pH, salinity, temperature, chemical and contamination load), use in combination with many disinfection processes: chlorine gas, sodium hypochlorite, calcium hypochlorite, electrolysis, use in a wide measuring range of 0.01 to 1,000 mg/l.
  • Precise, real-time amperometric measurement for efficient process control (short response time)
  • Amperometric measuring eliminates interference caused by turbidity or colouration
  • Stable zero point
  • Integrated temperature compensation eliminates interference caused by influence of temperature
  • For sensors with diaphragm-covered measuring electrodes: reduced dependence on flow, substances in water and film-forming media. Diaphragm-covered measuring electrodes embedded in an electrolyte ensure long service life. This maintains optimum measuring conditions regardless of process conditions. Low-cost maintenance thanks to easy diaphragm cap changes.

Technical Info

Free chlorine (hypochlorous acid HOCl)

  • CLE 3; pH: 5.5 … 8.0; Temp. 5 … 45 °C
  • CLE3.1; pH: 5.5 … 8.0; Temp. 5 … 45 °C
  • CLO 3; pH: 5.0 … 9.0; Temp. 5 … 45 °C
  • CLO 4; pH: 5.0 … 9.0; Temp. 5 … 70 °C
  • CLB 4; pH: 5.0 … 9.0; Temp. 5 … 45 °C
  • CLB 5; pH: 5.0 … 9.0; Temp. 5 … 45 °C
  • CBR 1; pH: 5.0 … 9.5; Temp. 5 … 45 °C
  • CLR 1; pH: 5.5 … 8.0; Temp. 5 … 45 °C

Your benefits

  • Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
  • Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
CLE 3-mAStandard sensor for measuring free chlorine in clear water. For operation on controllers with 4-20 mA input
Measured variableFree chlorine with a pH value < 8
Reference methodDPD1
pH-range5.5…8.0
Temperature5…45 °C
Max. pressure1.0 bar
FlowDGMa, DLG III: 30...60 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltage16...24 V DC (2-wire)
Output signal4-20 mA ≈ measuring range, temperature-compensated, uncalibrated, not electrically isolated
SelectivityFree chlorine as against combined chlorine, even if there is not an excess of it
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, disinfectants with organic chlorine, e. g. based on cyanuric acid, are unsuitable
Process integrationBypass: open sample water outlet
Sensor fittingBAMa, DGMa, DLG III
ControllersD1C, DAC, diaLog X, DULCOPOOL Pro
Typical applicationsCLE 3-mA-0,5 ppm: potable water; CLE 3-mA-2.0/10 ppm: swimming pools (surfactant-free).
Resistance toSalts, acids, alkalis. Not surfactants
Measuring principle, technologyAmperometric, 2 electrodes, diaphragm-covered
Measuring rangeOrder no.
CLE 3-mA-0.5 ppm0.01…0.5 mg/l792927
CLE 3-mA-2 ppm0.02…2.0 mg/l792920
CLE 3-mA-5 ppm0.05…5.0 mg/l1033392
CLE 3-mA-10 ppm0.10…10.0 mg/l792919
CLE 3-mA-20 ppm0.20…20.0 mg/l1002964
CLE 3-mA-50 ppm0.50…50.0 mg/l1020531
CLE 3-mA-100 ppm1.00…100.0 mg/l1022786

Chlorine sensors complete with 100 ml of electrolyte

A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.

Your benefits

  • Measured variable: free chlorine, no cross-sensitivity to combined chlorine (chloramines), even if there is an excess of it
  • Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
CLE 3.1-mASensor for the measurement of free chlorine in clear water with higher selectivity towards combined chlorine. For use on controllers with 4-20 mA input
Measured variableFree chlorine (hypochlorous acid HOCl) with high levels of combined chlorine; for determining the combined chlorine with a DAC controller and sensor for total chlorine type CTE 2-mA or type CTE 3-mA depending on application
Reference methodDPD1
pH-range5.5…8.0
Temperature5…45 °C
Max. pressure1.0 bar
FlowDGMa, DLG III: 30...60 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltage16...24 V DC (2-wire)
Output signal4-20 mA ≈ measuring range, temperature-compensated, uncalibrated, not electrically isolated
SelectivityFree chlorine as against combined chlorine, even if there is an excess of it
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, disinfectants with organic chlorine, e. g. based on cyanuric acid, are unsuitable
Process integrationBypass: open sample water outlet
Sensor fittingBAMa, DGMa, DLG III
ControllersdiaLog C, diaLog X, diaLog DACb, D1Cb/D1Cc, DULCOPOOL Pro, AEGIS II
Typical applicationsPotable water with higher volumes of combined chlorine, swimming pools. To determine the combined chlorine from the difference: Total chlorine minus free chlorine in the controller DAC.
Resistance toSalts, acids, alkalis. Not surfactants
Measuring principle, technologyAmperometric, 2 electrodes, diaphragm-covered
Measuring rangeOrder no.
CLE 3.1-mA-0.5 ppm0.01…0.5 mg/l1020530
CLE 3.1-mA-2 ppm0.02…2.0 mg/l1018369
CLE 3.1-mA-5 ppm0.05…5.0 mg/l1019398
CLE 3.1-mA-10 ppm0.10…10.0 mg/l1018368

Chlorine sensors complete with 100 ml of electrolyte

A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.

Your benefits

  • Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
  • Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
CLE 3-DMTStandard sensor for measuring free chlorine in clear water. For operation on ProMinent transmitters type DMT
Measured variableFree chlorine
Reference methodDPD1
pH-range5.5…8.0
Temperature5…45 °C
Max. pressure1.0 bar
FlowDGMa, DLG III: 30...60 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltage3.3 V DC (5 P)
Output signal0…1 V DC, uncalibrated, not temperature-compensated, not electrically isolated
Temperature measurementAbout the integrated Pt 1000. The temperature compensation is carried out in DMT.
SelectivityFree chlorine as against combined chlorine, even if there is not an excess of it
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, disinfectants with organic chlorine, e. g. based on cyanuric acid, are unsuitable
Process integrationBypass: open sample water outlet
Sensor fittingBAMa, DGMa, DLG III
ControllersDMTa
Typical applicationsCLE 3-mA-0,5 ppm: potable water; CLE 3-mA-2.0/10 ppm: swimming pools (surfactant-free).
Resistance toSalts, acids, alkalis. Not surfactants
Measuring principle, technologyAmperometric, 2 electrodes, diaphragm-covered
Measuring rangeOrder no.
CLE 3-DMT-5 ppm0.01…5.0 mg/l1005511
CLE 3-DMT-50 ppm0.10…50.0 mg/l1005512

Chlorine sensors complete with 100 ml of electrolyte

A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.

Your benefits

  • Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
  • Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
  • Operation on the CAN-bus with all the associated benefits
CLE 3-CANStandard sensor for measuring free chlorine in clear water. For use on controllers with CAN-bus connection
Measured variableFree chlorine
Reference methodDPD1
pH-range5…45 °C
Max. pressure1.0 bar
FlowDGMa, DLG III: 30...60 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltageVia CAN-interface (11 – 30 V)
Output signalUncalibrated, temperature compensated, electrically isolated
SelectivityFree chlorine as against combined chlorine, even if there is not an excess of it
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, disinfectants with organic chlorine, e. g. based on cyanuric acid, are unsuitable
Process integrationBypass: open sample water outlet
Sensor fittingBAMa, DGMa, DLG III
ControllersDULCOMARIN 3
Typical applicationsCLE 3-mA-0,5 ppm: potable water; CLE 3-mA-2.0/10 ppm: swimming pools (surfactant-free).
Resistance toSalts, acids, alkalis. Not surfactants
Measuring principle, technologyAmperometric, 2 electrodes, diaphragm-covered
Measuring rangeOrder no.
CLE 3-CAN-10 ppm0.01…10.0 mg/l1023425

Chlorine sensors complete with 100 ml of electrolyte

A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.

Your benefits

  • Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
  • Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
  • Operation on the CAN-bus with all the associated benefits
CLE 3.1-CANSensors for the measurement of free chlorine in clear water with higher selectivity towards combined clorine. For use on controllers with CAN-bus connection
Measured variable
Free chlorine with high levels of combined chlorine; for determining the combined chlorine with a DULCOMARIN and sensor for total chlorine type CTE 2-CAN or type CTE 3-CAN depending on application
Reference methodDPD1
pH-range5.5…8.0
Temperature5…45 °C
Max. pressure1.0 bar
FlowDGMa, DLG III: 30...60 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltageVia CAN-interface (11 – 30 V)
Output signalUncalibrated, temperature compensated, electrically isolated
Selectivityfree chlorine
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, disinfectants with organic chlorine, e. g. based on cyanuric acid, are unsuitable
Process integrationBypass: open sample water outlet
Sensor fittingBAMa, DGMa, DLG III
ControllersDULCOMARIN 3
Typical applicationsDrinking water with higher levels of combined chlorine; swimming pool. To determine the combined chlorine from the difference: Total chlorine minus free chlorine in the controller DULCOMARIN.
Resistance toSalts, acids, alkalis. Not surfactants
Measuring principle, technologyAmperometric, 2 electrodes, diaphragm-covered
Measuring rangeOrder no.
CLE 3.1-CAN-10 ppm0.01…10.0 mg/l1023426

Chlorine sensors complete with 100 ml of electrolyte

A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.

Your benefits

  • Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
  • Use when sample water is returned to the process line
  • Use at higher pressures
  • Avoidance of problems caused by electrolysis systems in which the electrodes are immersed directly into the sample water
  • Measurement of free chlorine up to pH 9
  • Measurement in seawater possible
  • Also suitable for use in film-forming water with optional “hydrodynamic cleaning”.
CLO 3-mASensor for the measurement of free chlorine in clear water, as well as in seawater, and when using electrolysis processes for disinfection, up to 45 °C (1 bar) or 8 bar (25 °C). For operation with controllers with 4-20 mA input. Also suitable for use in film-forming water with optional "hydrodynamic cleaning".
Reference methodDPD1
pH-range5.0…9.0
Temperature5…45 °C
Max. pressure8.0 bar (25 °C)
Flow
DGMa, DLG III: 30...60 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltage16...24 V DC (2-wire)
Output signal4-20 mA ≈ measuring range, temperature-compensated, uncalibrated, not electrically isolated
SelectivityFree chlorine as against combined chlorine
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, electrolysis without diaphragm with electrodes in the process
Process integrationBypass: open outlet or return of the sample water into the process line, inline: direct installation into the tubes with the INLI fitting
Sensor fittingBAMa: up to 7 bar/20 °C
DGMa up to 6 bar/30 °C
DLG III up to 1 bar/55 °C
INLI up to 7 bar/40 °C
ControllersdiaLog C, diaLog X, diaLog DACb, D1Cb/D1Cc, DULCOPOOL Pro, AEGIS II
Typical applicationsSwimming pools, drinking water, process water and in seawater, and can also be used together with diaphragm-free electrolysis processes. Can also be used in conjunction with hydrodynamic cleaning even in biofilm-forming water, or water containing lime, iron or manganese.
Resistance toSurfactants, films with using hydrodynamic cleaning
Measuring principle, technologyAmperometric, 3 electrodes, no diaphragm
Measuring rangeOrder no.
CLO 3-mA-2 ppm0.02…2.0 mg/l1131658
CLO 3-mA-10 ppm0.10…10.0 mg/l1131662

Your benefits

  • Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
  • Use when sample water is returned to the process line
  • Use at higher pressures
  • Avoidance of problems caused by electrolysis systems in which the electrodes are immersed directly into the sample water
  • Measurement in seawater possible
  • Also suitable for use in film-forming water with optional “hydrodynamic cleaning”.
CLO 3-CAN
Sensor for the measurement of free chlorine in clear water even when using electrolysis processes for disinfection, up to 45 °C (1 bar) or 8 bar (25 °C). For use on controllers with CAN-bus connection. Also suitable for use in film-forming water with optional “hydrodynamic cleaning”.
Measured variableFree chlorine
Reference methodDPD1
pH-range5.0…9.0
Temperature5…45 °C
Max. pressure8.0 bar (25 °C)
FlowDGMa, DLG III: 30...60 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltage11…30 V (via CAN interface)
Output signalDigital (CANopen), uncalibrated, temperature-compensated, electrically isolated
SelectivityFree chlorine as against combined chlorine
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, electrolysis without diaphragm with electrodes in the process
Process integrationBypass: open outlet or return of the sample water into the process line, inline: direct installation into the tubes with the INLI fitting
Sensor fittingBAMa: up to 7 bar/20 °C
DGMa up to 6 bar/30 °C
DLG III up to 1 bar/55 °C
INLI up to 7 bar/40 °C
ControllersDULCOMARIN 3
Typical applicationsSwimming pools, drinking water, process water and seawater, and can also be used together with diaphragm-free electrolysis processes. Can also be used in conjunction with hydrodynamic cleaning even in water that forms biofilms, or containing lime, iron or manganese.
Resistance toSalts, acids, lyes, surfactants, films of dirt, films when using hydrodynamic cleaning
Measuring principle, technologyAmperometric, 3 electrodes, no diaphragm
Measuring rangeOrder no.
CLO 3-CAN-10 ppm0.01…10.0 mg/l1133203

Your benefits

  • Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
  • Use when sample water is returned to the process line
  • Use at higher pressures/temperatures
  • Avoidance of problems caused by electrolysis systems in which the electrodes are immersed directly into the sample water
  • Measurement of free chlorine up to pH 9
  • Measurement in seawater possible
  • Also suitable for use in film-forming water with optional “hydrodynamic cleaning”
CLO 4-mASensor for the measurement of free chlorine in clear water, as well as in seawater, and when using electrolysis processes for disinfection, up to 70 °C or 8 bar (25 °C). For operation with controllers with 4-20 mA input. Also suitable for use in film-forming water with optional "hydrodynamic cleaning".
Measured variableFree chlorine
Reference methodDPD1
pH-range5.0…9.0
Temperature5…70 °C
Max. pressure8.0 bar (25 °C)
FlowDGMa, DLG III: 30...60 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltage16...24 V DC (2-wire)
Output signal4-20 mA ≈ measuring range, temperature-compensated, uncalibrated, not electrically isolated
SelectivityFree chlorine as against combined chlorine
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, electrolysis without diaphragm with electrodes in the process
Process integrationBypass: open outlet or return of the sample water into the process line, inline: direct installation into the tubes with the INLI fitting
Sensor fittingBAMa: up to 3 bar/70 °C
DGMa up to 1 bar/60 °C
DLG III up to 1 bar/55 °C
INLI up to 2 bar/70 °C
ControllersdiaLog C, diaLog X, diaLog DACb, D1Cb/D1Cc, DULCOPOOL Pro, AEGIS II
Typical applicationsHot water up to 70 °C, combating legionella, drinking water, process water and in seawater, can also be used together with diaphragm-free electrolysis processes. Can also be used in conjunction with hydrodynamic cleaning even in biofilm-forming water, or water containing lime, iron or manganese.
Resistance toSurfactants, films with using hydrodynamic cleaning
Measuring principle, technologyAmperometric, 3 electrodes, no diaphragm
Measuring rangeOrder no.
CLO 4-mA-2 ppm0.02…2.0 mg/l1131644

Your benefits

  • Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
  • Cost-effective due to its simple construction without separate wear parts
  • Simple, cost-effective maintenance without handling of the diaphragm caps
  • Avoidance of problems caused by electrolysis systems without a diaphragm in which the electrodes are immersed directly into the sample water
  • Measurement of free chlorine up to pH 9 and use at high pressure of up to 3 bar thanks to absence of a diaphragm
  • Measurement in seawater possible
CLB 4-µACost-effective, simple sensor for the measurement of free chlorine in clear water, also in seawater and with a changing media temperature. Can also be used with electrolysis processes for disinfection at up to 45 °C/3 bar. For operation with the Compact controller DCCa
Measured variableFree chlorine
Measuring range0.05 – 5.0 mg/l, can be used for short-term shock chlorination up to 10 mg/l
Reference methodDPD1
pH-range5.0…9.0
Temperature5…45 °C
Max. pressure3.0 bar
FlowDGMa, DLG III: 60...80 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltageOnly for compact controllers
Output signalUnamplified primary flow signal, temperature-compensated, uncalibrated, no electrical isolation.
SelectivityFree chlorine as against combined chlorine
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, electrolysis without diaphragm with electrodes in the process
Process integrationBypass: open sample water outlet, inline: direct installation into the pipework
Sensor fittingBAMa, DGMa, DLG III
ControllersCompact
Typical applicationsSwimming pools, potable water, seawater, can also be used with diaphragm-free electrolysis processes for chlorine generation, also suitable for use with fluctuating medium temperatures.
Resistance tosurfactants
Measuring principle, technologyAmperometric, 3 electrodes, no diaphragm
Measuring rangeOrder no.
CLB 4-µA-5 ppm0.05…5.0 mg/l1130517

Your benefits

  • Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
  • Cost-effective due to its simple construction without separate wear parts
  • Simple, cost-effective maintenance without handling of the diaphragm caps
  • Avoidance of problems caused by electrolysis systems without a diaphragm in which the electrodes are immersed directly into the sample water
  • Measurement of free chlorine up to pH 9 and use at high pressure of up to 3 bar thanks to absence of a diaphragm
  • Measurement in seawater possible
CLB 5-µACost-effective, simple sensor for the measurement of free chlorine in clear water, also in seawater and with a constant media temperature. Can also be used with electrolysis processes for disinfection at up to 45 °C/3 bar. For operation with the Compact controller DCCa
Measured variableFree chlorine
Measuring range0.05 - 5.0 mg/l: linear, can be used for shock chlorination up to 10.0 mg/l
Reference methodDPD1
pH-range5.0…9.0
Electrolytic conductivity0.05...50 mS/cm
Temperature5…45 °C
Max. pressure3.0 bar
FlowDGMa, DLG III: 60...80 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltageOnly for compact controllers
Output signalNon-amplified primary current signal, not temperature-compensated, uncalibrated, not electrically isolated
Temperature measurementNone
SelectivityFree chlorine as against combined chlorine
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, electrolysis without diaphragm with electrodes in the process
Process integrationBypass: open sample water outlet, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting)
Sensor fittingBAMa, DGMa, DLG III
Electrical ConnectionFixed cable, 1 m, 4 wires with cable end sleeves
ControllersCompact
Typical applicationsSwimming pools, potable water, sea water; also suitable for use with diaphragm-free electrolysis processes for chlorine generation.
Resistance tosurfactants
Measuring principle, technologyAmperometric, 3 electrodes, no diaphragm
Measuring rangeOrder no.
CLB 5-µA-5 ppm0.05…5.0 mg/l1104626

Your benefits

  • Measured variable: free chlorine, as well as free and combined bromine (bromamines)
  • Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water
  • Resistance to films of dirt and biofilms by electrolyte with antimicrobial effect and large-pore diaphragm
  • Use at high pH value of up to 9.5 by optimisation of the electrolyte diaphragm system
CBR 1-mASensor for free chlorine and bromine in contaminated water, also suitable for high pH values of up to 9.5. For use with controllers with 4-20 mA input
Measured variablefree chlorine, free bromine, combined bromine, DBDMH (1,3-dibrom-5,5-dimethyl-hydantoin)
Reference methodDPD1
pH-range5.0…9.5
Temperature1…40 °C
Max. pressure1.0 bar
FlowDGMa: 20...80 l/h
DLG III: 40...100 l/h
BAMa: 5...100 l/h (depending on design)
Supply voltage16...24 V DC (2-wire)
Output signal4-20 mA ≈ measuring range, temperature-compensated, uncalibrated, not electrically isolated
SelectivityFree chlorine as against combined chlorine
Disinfection processChlorine gas, hypochlorite, electrolysis with diaphragm, bromide + hypochlorite
Process integrationBypass: open sample water outlet
Sensor fittingBAMa, DGMa, DLG III
ControllersdiaLog C, diaLog X, diaLog DACb, D1Cb/D1Cc, DULCOPOOL Pro, AEGIS II
Typical applications
Cooling water, process water, waste water, water with higher pH values (stable pH), contaminated swimming pool water. Raw water for drinking water treatment.
Resistance toSalts, acids, alkalis, surfactants, dirt films
Measuring principle, technologyAmperometric, 2 electrodes, diaphragm-covered
Measuring rangeOrder no.
CBR 1-mA-0.5 ppm0.01…0.5 mg/l *1038016
CBR 1-mA-2 ppm0.02…2.0 mg/l *1038015
CBR 1-mA-5 ppm0.05…5.0 mg/l *1052138
CBR 1-mA-10 ppm0.10…10.0 mg/l *1038014

* Measuring range based on chlorine. When measuring bromine, the lower and upper limit of the measuring range are increased by the factor 2.25, therefore for example CBR 1-mA-0.5ppm: 0.02 …1.1 ppm.

Brand